PPEs Coveralls are used as barrier against infectious contaminated objects
- Effective filter for the infectious contaminated objects
- Barrier to stop cross contamination spread through various infections such as nosocomial infections, human fluid contaminants such as blood, perspiration, saliva, omit, semen, feces, urine and skin cells
- Transmission of microorganisms through PPEs depends upon various factors such as
- Pore size (filtering capacity), Thickness, Repellency of PPE
- Morphology, size, shape and, adaptation of environment
- Surface tension, volume, viscosity and force
- Physical, thermal, chemical and environmental stresses
- Type of carriers (body fluids, sloughed skin cells, lint, dust, respiratory droplets and aerosolized molecules
WRA has created following Services for Meeting the current requirement of PPE items testing.
Test Parameter | Test Method | Sample Requirement |
---|---|---|
1. Fabric Weight | ASTM D 3776/IS 1964/ISO 3801 | 0.25mts |
2. Tensile Strength | EN ISO 13934-1 | 0.5 mtrs |
3. Tear Strength | IS 6489/ISO 13937-1/ ISO 13937-2/ISO 13937-3 | 0.5 mtrs |
4. Bursting Strength | ISO 1396938-1/ISO 9073-5/IS 1966 | 0.5 mtrs |
5. Seam/Joint Strength | ISO 13935-1/ISO 13935-2 | 0.5 mtrs |
6. Water Repellency | AATCC 22/IS 390/ ISO 1920 | 0.5 mtrs |
7. Impact Penetration | AATCC 22 | 0.5 mtrs |
8. Hydrostatic Head test | ISO 811/AATCC 127 | 0.5 mtrs |
9. Moisture Vappour Transmission Rate (MVTR) | ASTM E 96 | 0.25 mtrs |
10. Water Vapour Resistance (Ret)-breathability | ISO 11092/ASTM F 1868 part B/ IS17334 Table I(x) | 0.5 mtrs |
11. Synthetic Blood Penetration | ISO 16603/ ASTm F 1670/ IS16546 | 0.5 mtrs |
12. Poresize | ASTM D 6767 | 0.25 mtrs |
13. Airpermeability | ASTM D 737/ISO 9237 | 0.5 mtrs |
14. Antistatic | EN 1149-5 (Testing based on EN 1149-1) | 0.5 mtrs |
15. Resistance to ignition | IS 6489/ISO 13937-1/ ISO 13937-2/ISO 13937-3 | 0.5 mtrs |
16. Antimicrobial Testing | AATCC 100 | 0.5 mtrs |
Specification: ANSI / AAMI PB70 | ||
1. Water Impact Test | AATCC 42 | 0.5mtrs |
2. Hydrostatic Head Test | AATCC 127 | 0.5 mtrs |
3. synthetic blood penetration | ASTM F 1670 | 0.25mtrs |
4. Blood borne pathogen penetration resistance | ASTM F 1671 | -- |
BS EN ISO 13982-1: 2004 Protective clothing for use against solid particulates (Type 5 Clothing)
Test Parameter | Test Method | Sample Requirement |
---|---|---|
1. Cleaning (Pretreatment) (Applicable only if material is washable) | Five cycles of cleaning according to the manufacturer's instructions before testing, if the manufacturer's instructions indicate that the garment can be cleaned | -- |
2. Abrasion Resistance | EN 530 | 0.25 meter |
3. Flex Cracking | EN ISO 7854 | 0.25 mtrs |
4. Trapezoidal tear resistance | EN ISO 9073-4/ ASTM D5733 | 0.50 mtrs |
5. Puncture Resistance | EN 863 | 0.25 mtrs |
6. Resistance to ignition | EN 13274-4 | 0.5 mtrs |
4.2.2 Seams, joins and assemblages (Applicable only for garment) | EN ISO 13935-2 | 0.5 mtrs specimens with seam at center |
4.3 Inward leakage of aerosols & solid particles (Only for Garment) | as per ISO 13982-2 | Not possible |
4.4 Visor | ISO 13982-1 | Not possible |
Specification: EN 14325:2004 (Chemical protective clothing general requirements) | ||
1. Abrasion Resistance | EN 530 up to 10000 rubs | 0.25 mtrs |
2. Trapezoidal Test Strength | EN ISO 9073-4 | 0.5 mtrs |
3. Tensile Strength | EN ISO 13934-1 | 0.5 mtrs |
4. Puncture resistance | EN 863 | 0.25 mtrs |
5. Flex Cracking | EN ISO 7854 Up to 25000 cycles Up to 50000 cycles Up to 1,00,000 cycles | 0.25 mtrs |
Specification: EN 13034, Type 6 Suit | ||
4.4 Abrasion Resistance | EN 530 up to 10000 rubs | 0.25mtrs |
4.7 Trapezoidal Test Strength | EN ISO 9073-4 | 0.5 mtrs |
4.9 synthetic blood penetration | EN ISO 13934-1 | 0.5mtrs |
4.10 Puncture resistance | EN 863 | 0.25mtrs |
4.12 Repellency of Liquid | EN ISO 6530 | 2mtrs |
4.13 Resistance to penetration by liquids | EN ISO 6530 | 2mtrs |
4.14 Resistance to ignition | EN 13274-4 | 0.5mtrs |
Specification EN 13795 : 2011 | ||
1. Resistance to microbial penetration(Dry) | ENISO 22612 | Not possibel |
2. Resistance to microbial penetration(Wet) | ENISO 22610 | Not possible |
3. Cleanliness-microbial | ENISO 11737-1 | Not possible |
4. Cleanliness-particulate matter | ENISO 9073-10 | Not possible |
5. Resistance to liquid penetration | EN 20811 | 0.5mtr |
6. Bursting strength (Dry) | ENISO 13938-1 | 0.25mtr |
7. Bursting strength (Wet) | ENISO 13938-1 | 0.25mtr |
8. Tensile strength (Dry) | EN 29073-3 | 0.5mtr |
9. Tensile strength (Wet) | EN 29073-3 | 0.5mtr |